pyharp-dump CLI

pyharp-dump writes spectroscopy products as NetCDF files. It supports single-species molecular products, CIA pair products, and gas-mixture products built from HITRAN line data plus CIA data from either HITRAN or the legacy Orton/Xiz H2 tables.

Basic Usage

Choose one subcommand, then choose the target with --species, --pair, or --composition where supported.

pyharp-dump xsection --species H2O --temperature-k 300 --pressure-bar 1 --wn-range=20,2500
pyharp-dump xsection --pair H2-He --temperature-k 300 --pressure-bar 1 --wn-range=20,2500
pyharp-dump xsection --pair H2-H2 --cia-model xiz --h2-state eq --temperature-k 300 --pressure-bar 1 --wn-range=20,2500
pyharp-dump transmission --composition H2:0.9,He:0.1,H2O:0.002 --path-length-km 1 --temperature-k 300 --pressure-bar 1 --wn-range=20,2500

Without --output, files are written under --output-dir using names derived from the target, product type, pressure, temperature, and wavenumber range. Generated names end with cm1 to indicate wavenumber bounds in cm^-1. For state-grid dumps, the state portion of the filename is <min_temp>_<max_temp>K_<min_pres>_<max_pres>bar.

Subcommands

xsection

Write absorption cross-section products.

Supported selectors:

  • --species for a molecular absorber

  • --pair for a CIA pair

  • --composition for a gas mixture

Examples:

pyharp-dump xsection --species CO2 --temperature-k 300 --pressure-bar 1 --wn-range=20,2500
pyharp-dump xsection --pair H2-He --temperature-k 300 --pressure-bar 1 --wn-range=20,10000
pyharp-dump xsection --pair H2-H2 --cia-model 2018 --h2-state nm --temperature-k 300 --pressure-bar 1 --wn-range=20,10000
pyharp-dump xsection --composition H2:0.9,He:0.1,CH4:0.004,H2O:0.002 --temperature-k 300 --pressure-bar 1 --wn-range=20,2500

transmission

Write transmission products over a fixed path length.

Supported selectors:

  • --species for a molecular absorber

  • --pair for a CIA pair

  • --composition for a gas mixture

Examples:

pyharp-dump transmission --species H2O --path-length-km 1 --temperature-k 300 --pressure-bar 1 --wn-range=20,2500
pyharp-dump transmission --pair H2-He --path-length-km 1 --temperature-k 300 --pressure-bar 1 --wn-range=20,10000
pyharp-dump transmission --pair H2-H2 --cia-model orton --h2-state eq --path-length-km 1 --temperature-k 300 --pressure-bar 1 --wn-range=20,10000
pyharp-dump transmission --composition H2:0.9,He:0.1,H2O:0.002 --path-length-km 1 --temperature-k 300 --pressure-bar 1 --wn-range=20,2500

Shared Options

--wn-range=min,max

Wavenumber bounds in cm^-1. Repeat this option to write one NetCDF file per band. When --output is provided with multiple ranges, pyharp appends _<wnmin>_<wnmax> to the requested stem. Ranges are inclusive at both ends, so --wn-range=20,22 with --resolution 1 samples 20, 21, and 22.

--resolution value

Wavenumber spacing in cm^-1. The default is 1.

--temperature-k value

Base temperature in kelvin. The default is 300. Use a comma-separated list such as 300,400,500 paired one-to-one with --pressure-bar.

--pressure-bar value

Pressure in bar. The default is 1. Use a comma-separated list paired one-to-one with --temperature-k.

--del-temperature-k value

Temperature anomalies in kelvin applied to each base (temperature, pressure) pair. The default is 0. For example, --temperature-k 300 --pressure-bar 1 --del-temperature-k -10,-5,0,5,10 evaluates the states 290, 295, 300, 305, 310 K at 1 bar.

--path-length-km value

Transmission path length in kilometers. This option is required only for transmission and defaults to 1.

--output path

Explicit NetCDF output path.

--output-dir path

Directory used for auto-generated NetCDF filenames. This is ignored when --output is provided.

--hitran-dir path

Directory used for cached HITRAN line and CIA files. The default is hitran.

--cia-dir path

Directory used for alternate CIA tables when --cia-model is xiz or orton. The default is orton_xiz_cia.

--cia-model value

CIA model selector for --pair workflows. auto, 2011, and 2018 use HITRAN. xiz and orton use the legacy H2 tables.

--h2-state {eq,nm}

H2 spin-state selector for --pair workflows. This affects HITRAN 2018 H2-H2 tables and the legacy xiz/orton tables. HITRAN 2011 does not distinguish eq and nm.

--refresh-hitran and --refresh-cia

Re-download cached HITRAN line or CIA inputs.

--broadening-composition BROADENER:FRACTION,...

Broadening gas composition for molecular line calculations. This affects line absorption only, not CIA-only --pair workflows.

Target Selection

Use --species for HITRAN line species such as CH4, CO2, H2, H2O, H2S, N2, and NH3.

Use --pair for CIA pairs such as H2-H2 and H2-He.

For pair workflows, --cia-model determines both the backend and the file family:

  • --cia-model auto uses the built-in HITRAN default filename mapping

  • --cia-model 2011 resolves H2-H2_2011.cia or H2-He_2011.cia

  • --cia-model 2018 --h2-state eq|nm resolves H2-H2_eq_2018.cia or H2-H2_nm_2018.cia

  • --cia-model xiz|orton --h2-state eq|nm resolves one of the downloaded legacy H2 tables

If a requested HITRAN pair/model/state combination has no configured file, pyharp raises an error instead of silently falling back to another CIA file.

Use --composition for gas mixtures:

--composition H2:0.9,He:0.1,CH4:0.004,H2O:0.002,NH3:0.0003

Broadening Behavior

If --broadening-composition is omitted for single-species molecular products, pyharp defaults to self broadening. For mixture workflows, pyharp defaults to the mixture composition itself as the requested line broadening composition.

If a requested foreign broadener is not available in the HITRAN table for the active absorber, pyharp falls back to air for that fraction and prints the effective broadening summary.

H2O MT_CKD continuum components

For H2O xsection products, pyharp-dump stores the MT_CKD self and foreign continua as two separate fields:

  • sigma_continuum_h2o_self_mt_ckd

  • sigma_continuum_h2o_foreign_mt_ckd

Both fields have units of cm^2 molecule^-1 and contain the corresponding unit-VMR MT_CKD component. They are not multiplied by the H2O mole fraction in the NetCDF file. No additional CLI option is required: the split fields are written automatically for both --species H2O and any --composition that contains H2O.

Keeping the two fields separate allows one opacity table to be reused for different atmospheric compositions. At run time, MoleculeLine calculates the local H2O volume mixing ratio from the concentration tensor and forms

\[\sigma_{\mathrm{cont}} = x_{\mathrm{H_2O}}\,\sigma_{\mathrm{self}} + \left(1-x_{\mathrm{H_2O}}\right)\sigma_{\mathrm{foreign}}.\]

The continuum attenuation is then the composition-weighted continuum cross section multiplied by the H2O number density. In other words, self and foreign describe the collision partner of an absorbing H2O molecule; they are not two additional atmospheric species.

The --broadening-composition option controls HITRAN line broadening only. It does not pre-weight these continuum fields. For a single-species --species H2O calculation, the diagnostic sigma_total corresponds to pure H2O. For --composition, sigma_total is evaluated using the requested mixture, while the two component fields remain unweighted so they can be used later with a different composition.

New MoleculeLine readers require both split fields when either one is present. They also remain compatible with an older table containing only sigma_continuum_h2o_mt_ckd; that legacy combined field is used directly and cannot be reweighted for a different H2O abundance. Conversely, an older reader that only recognizes the combined field cannot use a newly generated split-continuum table.

Multi-band Output

Repeat --wn-range to compute multiple bands in one run:

pyharp-dump xsection --species H2O --temperature-k 300 --pressure-bar 1 \
    --wn-range=20,2500 --wn-range=2500,10000

This writes one file for [20, 2500] and one file for [2500, 10000]. Adjacent repeated ranges duplicate the shared boundary sample. If --output output/h2o.nc is provided, the generated files are output/h2o_20_2500.nc and output/h2o_2500_10000.nc.

Auto-generated filenames follow the pattern <target>_<product>_<min_temp>_<max_temp>K_<min_pres>_<max_pres>bar_<wnmin>_<wnmax>cm1.

State Grid Output

Dump products are always written on the dimensions (del_temperature, pressure, wavenumber). The pressure coordinate stores the paired --pressure-bar values converted to Pa, del_temperature stores the requested anomalies, and the temperature data variable has dimensions (pressure,) with the base temperatures from --temperature-k.

Even a single (temperature, pressure) pair is written with degenerate del_temperature and pressure dimensions of length one.

Parallel execution is flattened across all requested wn_range × pressure × del_temperature jobs.

NetCDF Naming Conventions

The dump CLI uses semantic field names and stores physical units in variable attributes rather than in variable names.

Xsection outputs

Single-species xsection dumps use names such as:

  • sigma_line_h2o

  • sigma_continuum_h2o_self_mt_ckd

  • sigma_continuum_h2o_foreign_mt_ckd

  • sigma_cia_h2o_h2o

  • binary_absorption_coefficient_h2o_h2o

  • sigma_total

The two split MT_CKD fields contain unit-VMR self and foreign components. MoleculeLine weights them at runtime by xH2O and 1 - xH2O as described in H2O MT_CKD continuum components.

Pair xsection dumps use:

  • binary_absorption_coefficient

Composition xsection dumps contain one file with multiple component fields:

  • sigma_line_<species> for unweighted line cross sections

  • sigma_continuum_h2o_self_mt_ckd and sigma_continuum_h2o_foreign_mt_ckd for unit-VMR H2O continuum components, weighted by MoleculeLine at runtime

  • binary_absorption_coefficient_<pair> for unweighted CIA binary coefficients

  • sigma_total for the composition-weighted total cross section

For composition xsection dumps, component fields are not weighted by mole fraction. Only sigma_total represents the weighted mixture result.

Transmission outputs

Transmission dumps follow the same component naming pattern and add weighted attenuation coefficients in m^-1.

Examples:

  • transmittance_line_h2o

  • attenuation_line_h2o

  • transmittance_continuum_h2o_mt_ckd

  • attenuation_continuum_h2o_mt_ckd

  • transmittance_cia_h2_he

  • attenuation_cia_h2_he

  • transmittance_total

  • attenuation_total

Unlike xsection output, a transmission product has already been evaluated for the selected species or composition and path length. Its H2O continuum variables therefore contain the combined, composition-weighted self-plus-foreign continuum and retain the unsplit *_continuum_h2o_mt_ckd names. They are diagnostic transmission products, not reusable MoleculeLine opacity-table inputs.

Global Attributes

Species and pair dumps include species_name plus the thermodynamic state.

Composition dumps include both:

  • composition_input with the original input string

  • species_name as a plain comma-separated species list such as H2,He,CH4,H2O,NH3

Examples

Single-species xsection with custom broadening:

pyharp-dump xsection \
    --species H2O \
    --temperature-k 300 \
    --pressure-bar 1 \
    --broadening-composition H2:0.9,He:0.1 \
    --wn-range=20,2500

Multi-band xsection in one run:

pyharp-dump xsection \
    --species H2O \
    --temperature-k 300 \
    --pressure-bar 1 \
    --wn-range=20,2500 \
    --wn-range=2500,10000

Paired state grid with temperature anomalies:

pyharp-dump xsection \
    --species H2O \
    --temperature-k 300,400 \
    --pressure-bar 1,10 \
    --del-temperature-k -10,-5,0,5,10 \
    --wn-range=20,2500

Composition transmission dump:

pyharp-dump transmission \
    --composition H2:0.9,He:0.1,CH4:0.004,H2O:0.002 \
    --path-length-km 1 \
    --temperature-k 300 \
    --pressure-bar 1 \